@@ -1233,14 +1233,14 @@ As it was not possible to reproduce the usual $I_{DD}0$ pattern of ACT-PRE for t
|
||||
The initial simulations are based on the current values specified in the datasheet of the specific vendor.
|
||||
Then, based on the actual measurements, the current values are reapplied to a second simulation.
|
||||
The results are shown in Figure~\ref{fig:power_plot}.
|
||||
%\begin{figure}
|
||||
% \begin{figure}
|
||||
% \centering
|
||||
% \resizebox{\linewidth}{!}{%
|
||||
% \input{img/power_plot}
|
||||
% }
|
||||
% \caption{Average Power Consumption of Simulations and Measurements for Different Vendors}
|
||||
% \label{fig:power_plot}
|
||||
%\end{figure}
|
||||
% \end{figure}
|
||||
As it can be seen, the $I_{DD}$ currents in the datasheet are overly pessimistic for all vendors:
|
||||
The simulations based on the datasheets show on average a $4.8\times$ higher power consumption than the actual power measurements.
|
||||
However, when the measured currents are applied to the simulation, there is still a small discrepancy:
|
||||
|
||||
@@ -193,9 +193,7 @@ series = {ASPLOS '18}
|
||||
publisher = {{ACM}},
|
||||
author = {Feldmann, Johannes and Steiner, Lukas and Christ, Derek and Psota, Thomas and Jung, Matthias and Wehn, Norbert},
|
||||
urldate = {2024-11-14},
|
||||
date = {2023-10-02},
|
||||
langid = {english},
|
||||
file = {Feldmann et al. - 2023 - A Precise Measurement Platform for LPDDR4 Memories.pdf:/home/derek/.local/share/zotero/storage/C7RSPK9K/Feldmann et al. - 2023 - A Precise Measurement Platform for LPDDR4 Memories.pdf:application/pdf},
|
||||
date = {2023-10-02}
|
||||
}
|
||||
|
||||
@inproceedings{vog_10,
|
||||
|
||||
@@ -45,7 +45,7 @@
|
||||
\addplot[color=green!50] table [x={time}, y={datasheet}]{\hynix};
|
||||
\addplot[color=blue!50] table [x={time}, y={measured}]{\hynix};
|
||||
\addplot[color=red!50] table [x={time}, y={optimized}]{\hynix};
|
||||
\addplot[color=brown!50] table [x={time}, y={optimized_no_if}]{\hynix};
|
||||
% \addplot[color=red!50] table [x={time}, y={optimized_no_if}]{\hynix};
|
||||
|
||||
\nextgroupplot[
|
||||
title=Vendor 2,
|
||||
@@ -67,7 +67,7 @@
|
||||
\addplot[color=green!50] table [x={time}, y={datasheet}]{\micron};
|
||||
\addplot[color=blue!50] table [x={time}, y={measured}]{\micron};
|
||||
\addplot[color=red!50] table [x={time}, y={optimized}]{\micron};
|
||||
\addplot[color=brown!50] table [x={time}, y={optimized_no_if}]{\micron};
|
||||
% \addplot[color=red!50] table [x={time}, y={optimized_no_if}]{\micron};
|
||||
|
||||
\nextgroupplot[
|
||||
title=Vendor 3,
|
||||
@@ -89,7 +89,7 @@
|
||||
\addplot[color=green!50] table [x={time}, y={datasheet}]{\samsung};
|
||||
\addplot[color=blue!50] table [x={time}, y={measured}]{\samsung};
|
||||
\addplot[color=red!50] table [x={time}, y={optimized}]{\samsung};
|
||||
\addplot[color=brown!50] table [x={time}, y={optimized_no_if}]{\samsung};
|
||||
% \addplot[color=red!50] table [x={time}, y={optimized_no_if}]{\samsung};
|
||||
\end{groupplot}
|
||||
|
||||